CyberPower UT850EG guarantees power protection for computers, networking equipment, and storage devices. The product adopts line-interactive topology with Automatic Voltage Regulation (AVR) function to offer stabilized AC power output. The patented GreenPower UPS™ Bypass design achieves ultra-low power consumption to reduce energy costs, and allows a lower operation temperature which extends battery lifespan. The LED indicator shows the utility, battery and operating status of the UPS. It is also compatible with generators to extend power continuity. Other features include overload protection, EMI filter and configurable alarm to safeguard your devices. Its tower design allows users to place it easily on desks or other tight spaces.
FEATURES
Energy Saving Technology
Generator Compatible
Overload Protection
Phone/Fax/Modem/DSL/Network Protection
USB Connectivity Port
Configurable Alarm
Automatic Voltage Regulation (AVR)
LED Status Indicator
Surge and Spike Protection
High-speed Ethernet Data Transmission
PowerPanel Management Software
EMI and RFI Filtration
WHAT'S IN THE BOX
UT850EG UPS
Product Registration Card
Quick Start Guide
* Product contents may vary according to different regions. For detailed information, please refer to user's manual/quick start guide.
AWARDS & CERTIFICATION
GreenPower UPS™
GreenPower UPS™ Technology improves operating efficiency and minimizes energy consumption, so that users can enjoy significant energy cost savings over conventional UPS systems.
GENERAL
Phase
Single Phase
Form Factor
Tower
UPS Topology
Line-interactive
Energy Saving Technology
GreenPower UPS™ Bypass Technology
INPUT
Generator Compatibility
Yes
Nominal Input Voltage ( Vac )
230 ± 10%
Input Voltage Range ( Vac )
165 ~ 290
Input Frequency ( Hz )
50 ± 5
60 ± 5
Input Frequency Detection
Auto-sensing
Rated Input Current ( A )
3.69
Input Connector Type
Schuko
?
Power Cord Length (ft.)
4
Power Cord Length (m.)
1.2
OUTPUT
Capacity (VA)
850
Capacity (Watts)
425
On Battery Waveform
Simulated Sine Wave
On Battery Voltage(s) ( Vac )
230 ± 10%
On Battery Frequency ( Hz )
50 ± 1%
60 ± 1%
Automatic Voltage Regulation (AVR)
Single Boost, Single Buck
Overload Protection
Internal Current Limiting, Fuse
Outlet(s) - Total
3
Outlet Type
Schuko x 3
?
Outlet(s) - Battery & Surge Protected
3
Typical Transfer Time ( ms )
4
BATTERY
Runtime at 60W ( min )
30
Runtime at 90W ( min )
20
Runtime at 200W ( min )
6
Typical Recharge Time ( Hours )
6
Start On Battery
Yes
User-replaceable
No
Battery Type
Sealed Lead-acid
SURGE PROTECTION & FILTERING
Surge Suppression ( Joules )
125
EMI/RFI Filtration
Yes
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out
MANAGEMENT & COMMUNICATIONS
LED Indicators
Power On, Line Mode, Battery Mode, Bypass Mode, Low Battery, Overload, UPS Fault